Name:Bortezomib
CAS No:179324-69-7

PRODUCT DESCRIPTION


  Bortezomib  Intermediates click here


【Name】


Bortezomib
【Iupac name】
[(1R)-3-methyl-1-[[(2S)-3-phenyl-2-(pyrazine-2-carbonylamino)propanoyl]
amino]butyl]boronic acid
【CAS Registry number】
179324-69-7
【Synonyms】
Pyz-Phe-boroLeu
Boronic acid, [(1(R)-3-methyl-1-[[(2S)-1-oxo-3-phenyl-2-[(pyrazinylcarbonyl)amino]propyl]amino]butyl]-
Boronic acid, [1-[[1-oxo-3-phenyl-2-[(2-pyrazinylcarbonyl) amino]propyl]amino]-3-methylbutyl]-, L-(S)-
[(1R)-3-methyl-1-[[(2S)-3-phenyl-2-(pyrazine-2-carbonylamino)propanoyl]amino]butyl]boronic acid
PS 341 (pharmaceutical)
【Molecular Formula】
C19H25BN4O4 (Products with the same molecular formula)
【Molecular Weight】
384.24
【Inchi】
InChI=1/C19H25BN4O4/c1-13(2)10-17(20(27)28)24-18(25)15(11-14-6-4-3-5-7-14)23-19(26)16-12-21-8-9-22-16/h3-9,12-13,15,17,27-28H,10-11H2,1-2H3,(H,23,26)(H,24,25)/t15-,17-/m1/s1
【Canonical SMILES】
B(C(CC(C)C)NC(=O)C(CC1=CC=CC=C1)NC(=O)C2=NC=CN=C2)(O)O
【Isomers smiles】
B([C@H](CC(C)C)NC(=O)[C@H](CC1=CC=CC=C1)NC(=O)C2=NC=CN=C2)(O)O
【MOL File】
179324-69-7.mol

Chemical and Physical Properties

【Appearance】
yellow solid
【Density】
1.214
【Melting Point】
122-124℃
【Refractive Index】
1.564
【Solubilities】
In water, 3.3 to 3.8 mg/mL in a pH range of 2 to 6.5 (as the monomeric boronic acid)
In water, 76 mg/L at 25 deg C (est)
【Color/Form】
Powder
【Computed Properties】
Molecular Weight:384.2372 [g/mol]
Molecular Formula:C19H25BN4O4
H-Bond Donor:4
H-Bond Acceptor:6
Rotatable Bond Count:9
Tautomer Count:4
Exact Mass:384.196886
MonoIsotopic Mass:384.196886
Topological Polar Surface Area:124
Heavy Atom Count:28
Formal Charge:0
Complexity:500
Isotope Atom Count:0
Defined Atom Stereocenter Count:2
Undefined Atom Stereocenter Count:0
Defined Bond Stereocenter Count:0
Undefined Bond Stereocenter Count:0
Covalently-Bonded Unit Count:1

Safety and Handling

【Cleanup Methods】
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Spill kits containing all materials needed to clean up spills of hazardous drugs should be assembled or purchased. These kits should be readily available in all areas where hazardous drugs are routinely handled. If hazardous drugs are being prepared or administered in a nonroutine area (home setting or unusual patient-care area), a spill kit should be obtained by the drug handler. The kit should include two pairs of disposable gloves (one outer pair of utility gloves and one inner latex pair); low-permeability, disposable protective garments (coveralls or gown and shoe covers); safety glasses or splash goggles; respirator; absorbent, plastic-backed sheets or spill pads; disposable toweling; at least 2 sealable thick plastic hazardous waste disposal bags (prelabeled with an appropriate warning label); a disposable scoop for collecting glass fragments; and a puncture-resistant container for glass fragments. All individuals who routinely handle hazardous drugs must be trained in proper spill management and cleanup procedures. Spills and breakages must be cleaned up immediately according to the following procedures. If the spill is not located in a confined space, the spill area should be identified and other people should be prevented from approaching and spreading the contamination. Wearing protective apparel from the spill kit, workers should remove any broken glass fragments and place them in the puncture-resistant container. Liquids should be absorbed with a spill pad; powder should be removed with damp disposable gauze pads or soft toweling. The hazardous material should be completely removed and the area rinsed with water and then cleaned with detergent. The spill cleanup should proceed progressively from areas of lesser to greater contamination. The detergent should be thoroughly rinsed and removed. All contaminated materials should be placed in the disposal bags provided and sealed and transported to a designated containment receptacle. Spills occurring in the biohazard cabinet should be cleaned up immediately; a spill kit should be used if the volume exceeds 150 ml or the contents of one drug vial or ampule. If there is broken glass, utility gloves should be worn to remove it and place it in the puncture-resistant container located in the biohazard cabinet. The biological safety cabinet, including the drain spillage trough, should be thoroughly cleaned. If the spill is not easily and thoroughly contained, the biological safety cabinet should be decontaminated after cleanup. If the spill contaminates the high efficiency particulate air filter, use of the biological safety cabinet should be suspended until the cabinet has been decontaminated and the high efficiency particulate air filter replaced. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ If hazardous drugs are routinely prepared or administered in carpeted areas, special equipment is necessary to remove the spill. Absorbent powder should be substituted for pads or sheets and left in place on the spill for the time recommended by the manufacturer. The powder should then be picked up with a small vacuum unit reserved for hazardous drug cleanup. The carpet should then be cleaned according to usual procedures. The vacuum bag should be removed and discarded or cleaned, and the exterior of the vacuum cleaner should be washed with detergent and rinsed before being covered and stored. The contaminated powder should be discarded into a sealable plastic bag and segregated with other contaminated waste materials. Alternatively, inexpensive wet or dry vacuum units may be purchased for this express use and used with appropriate cleaners. All such units are contaminated, once used, and must be cleaned, stored, and ultimately discarded /properly/ ... The circumstances and handling of spills should be documented. Health-care personnel exposed during spill management should also complete an incident report or exposure form. /Antineoplastic agents/
【Formulations/Preparations】
Parenteral injection for iv use only, 3.5 mg (bortezomib) Velcade, Millennium Pharmaceuticals
... provided as a mannitol boronic ester which, in reconstituted form, consists of the mannitol ester in equilibrium with its hydrolysis product, the monoboronic acid. The drug substance exists in its cyclic anhydride form as a trimeric boroxine
【Exposure Standards and Regulations】
The Approved Drug Products with Therapeutic Equivalence Evaluations List identifies currently marketed prescription drug products, incl bortezomib, approved on the basis of safety and effectiveness by FDA under sections 505 of the Federal Food, Drug, and Cosmetic Act.
【Other Preventative Measures】
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Accidental contamination of the health-care environment, resulting in exposure of personnel, patients, visitors, and family members to hazardous substances, is prevented by maintaining the physical integrity and security of packages of hazardous drugs. 1. Access to all areas where hazardous drugs are stored is limited to specified authorized staff. 2. A method should be present for identifying to personnel those drugs that require special precautions (eg, cytotoxics). One way to accomplish this is to apply appropriate warning labels to all hazardous drug containers, shelves, and bins where the drug products are stored. ... 3. A method of identifying, for patients and family members, those drugs that require special precautions in the home should be in place. This may be accomplished in the health-care setting, by providing specific labeling for discharge medications, along with written instructions. 4. Methods for identifying shipping cartons of hazardous drugs should be required from manufacturers and distributors of these drugs. 5. Written procedures for handling damaged packages of hazardous drugs should be maintained. Personnel involved in shipping and receiving hazardous drugs should be trained in these procedures, including the proper use of protective garments and equipment. Damaged shipping cartons of hazardous drugs should be received and opened in an isolated area (eg, in a laboratory fume hood, if available, not in a vertical laminar airflow biological safety cabinet used for preparing sterile products). /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Facilities (eg, shelves, carts, counters, and trays) for storing hazardous drugs are designed to prevent breakage and to limit contamination in the event of leakage. Bins, shelves with barriers at the front, or other design features that reduce the chance of drug containers falling to the floor should be used. Hazardous drugs requiring refrigeration should be stored separately from nonhazardous drugs in individual bins designed to prevent breakage and to contain leakage. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Until the reproductive risks (or lack thereof) associated with handling hazardous drugs within a safety program have been substantiated, staff who are pregnant or breast-feeding should be allowed to avoid contact with these drugs. Policies should be in effect that provide these individuals with alternative tasks or responsibilities if they so desire. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ The pharmacy should provide access to information on toxicity, treatment of acute exposure (if available), chemical inactivators, solubility and stability of hazardous drugs (including investigational agents) used in the workplace. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Appropriate engineering controls should be in place to protect the drug product from microbial contamination and to protect personnel and the environment from the potential hazards of the product. These engineering controls should be maintained according to applicable regulations and standards. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Biological safety cabinets should be cleaned and disinfected regularly to ensure a proper environment for preparation of sterile products. For routine cleanups of surfaces between decontaminations, water should be used (for injection or irrigation) with or without a small amount of cleaner. If the contamination is soluble only in alcohol, then 70% isopropyl or ethyl alcohol may be used in addition to the cleaner. In general, alcohol is not a good cleaner, only a disinfectant, and its use in a biohazard cabinet should be limited. The biohazard cabinet should be disinfected with 70% alcohol before any aseptic manipulation is begun. The excessive use of alcohol should be avoided in biohazard cabinets where air is recirculated ... because alcohol vapors may build up in the cabinet. A lint-free, plastic-backed disposable liner may be used in the biological safety cabinet to facilitate spill cleanup. ... If used, the liner should be changed frequently ... /or/ whenever it is overtly contaminated. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ The biological safety cabinets should be decontaminated on a regular basis (ideally at least weekly) and whenever there is a spill or the biological safety cabinet is moved or serviced, including for certification. ... Currently, no single reagent will deactivate all known hazardous drugs; therefore, decontamination of a biological safety cabinet used for such drugs is limited to removal of contamination from a nondisposable surface (the cabinet) to a disposable surface (eg, gauze or towels) by use of a good cleaning agent that removes chemicals from stainless steel. The cleaning agent selected should have a pH approximating that of soap and be appropriate for stainless steel. Cleaners containing chemicals such as quaternary ammonium compounds should be used with caution, because they may be hazardous to humans and their vapors may build up in any biological safety cabinet where air is recirculated. Similar caution should be used with any pressurized aerosol cleaner; spraying a pressurized aerosol into a biological safety cabinet may disrupt the protective containment airflow, damage the high efficiency particulate air filter, and cause an accumulation of the propellant within a biological safety cabinet where air is recirculated, resulting in a fire and explosion hazard. During decontamination, the operator should wear a disposable closed front gown, disposable latex gloves covered by disposable utility gloves, safety glasses or goggles, a hair covering, and a disposable respirator, because the glass shield of the biological safety cabinet occasionally must be lifted. The blower must be left on, and only heavy toweling or gauze should be used in the biological safety cabinet to prevent it from being "sucked" up the plenum and into the high efficiency particulate air filter. Decontamination should be done from top to bottom (areas of lesser contamination to greater) by applying the cleaner, scrubbing, and rinsing thoroughly with distilled or deionized water. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ The high efficiency particulate air filters /or other exhaust scrubbing system/ of the biohazard cabinet must be replaced whenever they restrict required airflow velocity or if they are overtly contaminated (eg, by a breach in technique that causes hazardous drug to be introduced onto the clean side of the supply high efficiency particulate air filter). Personnel and environmental protection must be maintained during replacement of a contaminated high efficiency particulate air filter. Because replacement of a high efficiency particulate air filter generally requires breaking the integrity of the containment aspect of the cabinet, this procedure may release contamination from the filter into the pharmacy or intravenous preparation area if carried out in an inappropriate manner. Before replacement of a high efficiency particulate air filter contaminated with hazardous drugs, the biological safety cabinet service agent should be consulted for a mutually acceptable procedure for replacing and subsequently disposing of a contaminated high efficiency particulate air filter. One procedure would include moving the biological safety cabinet to a secluded area or using plastic barriers to segregate the contaminated area. Protective clothing and equipment must be used by the servicer. The biological safety cabinet should be decontaminated before filter replacement. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ During removal of gloves, ... avoid touching the inside of the glove or the skin with the contaminated glove fingers. ... The worker should wear a protective disposable gown made of lint free, low-permeability fabric with a solid front, long sleeves, and tight-fitting elastic or knit cuffs when preparing hazardous drugs. Washable garments are immediately penetrated by liquids and therefore provide little, if any protection. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ When double gloving, one glove should be placed under the gown cuff and one over. The glove-gown interface should be such that no skin on the arm or wrist is exposed. Gloves and gowns should not be worn outside the immediate preparation area. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Eyewash fountains should be available in areas where hazardous drugs are routinely handled. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Although noninjectable dosage forms of hazardous drugs contain varying proportions of drug to nondrug (nonhazardous) components, there is potential for personnel exposure and environmental contamination with the hazardous components. Procedures should be developed to avoid the release of aerosolized powder or liquid into the environment during manipulation of these drugs. Drugs designated as hazardous should be labeled or otherwise identified as such to prevent their improper handling. Tablet and capsule forms of these drugs should not be placed in automated counting machines, which subject them to stress and may introduce powdered contaminants into the work area. During routine handling of hazardous drugs and contaminated equipment, workers should wear one pair of gloves of good quality and thickness. The counting and pouring of hazardous drugs should be done carefully, and clean equipment dedicated for use with these drugs should be used. ... When hazardous drug tablets in unit-of-use packaging are being crushed, the package should be placed in a small sealable plastic bag and crushed with a spoon or pestle; caution should be used not to break the plastic bag. Disposal of unused or unusable oral or topical dosage forms of hazardous drugs should be performed in the same manner as for hazardous injectable dosage forms and waste. ... Hazardous drug work areas should have a sink (preferably with an eyewash fountain) and appropriate first aid equipment to treat accidental skin or eye contact according to the protocol. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ A distinctive warning label with an appropriate CAUTION statement should be attached to all hazardous drug materials, consistent with state laws and regulations. This would include, for example, syringes, IV containers, containers of unit-dose tablets and liquids, prescription vials and bottles, waste containers, and patient specimens that contain hazardous drugs. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Supplies of disposable gloves and gowns, safety glasses, disposable plastic-backed absorbent liners, gauze pads, hazardous waste disposal bags, hazardous drug warning labels, and puncture-resistant containers for disposal of needles and ampuls should be conveniently located for all areas where hazardous drugs are handled. Assembling a "hazardous drug preparation and administration kit" is one way to furnish nursing and medical personnel with the materials needed to reduce the risk of preparing and administering a hazardous drug. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Prospective temporary and permanent employees who may be required to work with hazardous drugs should be so notified and should receive adequate information about the policies and procedures pertaining to their use. This notification should be documented during the interview process and retained as part of the employment record for all employees. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ All personnel involved with the transportation, preparation, administration, and disposal of cytotoxic and hazardous substances should continually be updated on new or revised information on safe handling of cytotoxic and hazardous substances. Policies and procedures should be updated accordingly. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ The work area should be designed to provide easy access to those items necessary to prepare, label, and transport final products; contain all related waste; and avoid inadvertent contamination of the work area. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Each health-care setting should have an established first aid protocol for treating cases of direct contact with hazardous drugs, many of which are irritating or caustic and can cause tissue destruction. Medical care providers in each setting should be contacted for input into this protocol. The protocol should include immediate treatment measures and should specify the type and location of medical follow-up and work-injury reporting. Copies of the protocol, highlighting emergency measures, should be posted wherever hazardous drugs are routinely handled. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Only individuals trained to administer hazardous drugs should be allowed to perform this function. Training programs should contain information on the therapeutic and adverse effects of these drugs and the potential, long term health risk to personnel handling these drugs. Each individual's knowledge and technique should be evaluated before administration of these drugs. This should be done by written examination and direct observation of the individual's performance. /Antineoplastic agents/
【Protective Equipment and Clothing】
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Protective apparel: Disposable closed-front gown or coveralls, disposable utility gloves over disposable latex gloves, NIOSH-approved air-purifying half-mask respirator equipped with a high efficiency filter, and eye protection should be worn. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Class 100 clean-air work stations, both horizontal and vertical airflow (with no containment characteristics), are inappropriate engineering controls for handling hazardous drugs because they provide no personnel protection and permit environmental contamination. Although there are no engineering controls designed specifically for the safe handling of hazardous chemicals as sterile products, Class II contained vertical-flow biological safety cabinets (biohazard cabinets) have been adopted for this use. Biohazard cabinetry is, however, designed for the handling of infectious agents, not hazardous chemicals. ... Based on design, ease of use, and cost considerations, Class II contained-vertical-flow biohazard cabinetry is currently recommended for use in preparing sterile doses of hazardous drugs. Class II cabinetry design and performance specifications are defined in NSF Standard 49. Biological safety cabinets selected for use with hazardous drugs should meet NSF Standard 49 specifications to ensure the maximum protection from these engineering controls. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Workers should wear powder free, disposable surgical latex gloves of good quality when preparing hazardous drugs. Selection criteria for gloves should include thickness (especially at the fingertips where stress is the greatest), fit, length, and tactile sensation. ... The practice of double gloving is supported by research that indicates that many glove materials vary in drug permeability even within lots; therefore, double gloving is recommended. ... In general, surgical latex gloves fit better, have appropriate elasticity for double gloving and maintaining the integrity of the glove-gown interface, and have sufficient tactile sensation (even during double gloving) for stringent aseptic procedures. ... Powdered gloves should be avoided. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Workers who are not protected by the containment environment of a biohazard cabinet should use respiratory protection when handling hazardous drugs. Respiratory protection should be an adjunct to and not a substitute for engineering controls. Surgical masks of all types provide no respiratory protection against powdered or liquid aerosols of hazardous drugs. In situations where workers may be exposed to potential eye contact with hazardous drugs, an appropriate plastic face shield or splash goggles should be worn. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ During compounding of hazardous drugs (eg, crushing, dissolving, and preparing an ointment), workers should wear low permeability gowns and double gloves. Compounding should take place in a protective area such as a disposable glove box. If compounding must be done in the open, an area away from drafts and traffic must be selected, and the worker should use appropriate respiratory protection. /Antineoplastic agents/
【Specification】

?Bortezomib (CAS NO.179324-69-7), its Synonyms are ((1R)-3-Methyl-1-(((2S)-3-phenyl-2-((pyrazinylcarbonyl)amino)propanoyl)amino)butyl)boronic acid ; Boronic acid, ((1R)-3-methyl-1-(((2S)-1-oxo-3-phenyl-2-((pyrazinylcarbonyl)amino)propyl)amino)butyl)- ; N-((1S)-1-Benzyl-2-(((1R)-1-(dihydroxyboranyl)-3-methylbutyl)amino)-2-oxoethyl)pyrazinecarboxamide ; Velcade . It is yellow solid.

【Octanol/Water Partition Coefficient】
log Kow = 2.0 (est)
【Disposal Methods】
SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ All contaminated disposables should be contained in sealable bags for transfer to larger waste containers. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ All bottles must be discarded as contaminated waste after decontamination of the biohazard cabinet. All protective apparel (gown, gloves, goggles, and respirator) should be discarded as contaminated waste. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ The contaminated filters must be removed, bagged in thick plastic and prepared for disposal in a hazardous waste dump site or incinerator licensed by the Environmental Protection Agency (EPA). /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ The gown should be removed and placed in a sealable container before removal of the inner gloves. The inner gloves should be removed last and placed in the container with the gown. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Hazardous drug waste should be placed in specially marked (specifically labeled CAUTION: HAZARDOUS CHEMICAL WASTE) thick plastic bags or leakproof containers. These receptacles should be kept in all areas where the drugs are commonly used. All and only hazardous drug waste should be placed in them. Receptacles used for glass fragments, needles, and syringes should be puncture resistant. Hazardous drug waste should not be mixed with any other waste. Waste containers should be handled with uncontaminated gloves. ... Gloves, gowns, drug vials, etc, should be sealed in specially labeled (CAUTION: HAZARDOUS CHEMICAL WASTE) thick plastic bags or leakproof containers. ... All hazardous waste collected from drug preparation and patient-care areas should be held in a secure place in labeled, leakproof drums or cartons (as required by state or local regulation or disposal contractor) until disposal. This waste should be disposed of as hazardous or toxic waste in an EPA-permitted state-licensed hazardous waste incinerator. Transport to an offsite incinerator should be done by a contractor licensed to handle and transport hazardous waste. ... If access to an appropriately licensed incinerator is not available, transport to and burial in an EPA-licensed hazardous waste dump site is an acceptable alternative. While there are concerns that destruction of carcinogens by incineration may be incomplete, newer technologies and stringent licensing criteria have improved this disposal method. ... Chemical deactivation of hazardous drugs should be undertaken only by individuals who are thoroughly familiar with the chemicals and the procedures required to complete such a task. The IARC recently published a monograph describing methods for chemical destruction of some cytotoxic (antineoplastic) drugs in the laboratory setting. The chemicals and equipment described, however, are not generally found in the clinical setting, and many of the deactivating chemicals are toxic and hazardous. Most procedures require the use of a chemical fume hood. The procedures are generally difficult, and the deactivation is not always complete. Serious consideration should be given to the negative aspects of chemical deactivation before one commits to such a course of action. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ Regulatory agencies such as the EPA and state solid and hazardous waste agencies and local air and water quality control boards must be consulted regarding the classification and appropriate disposal of drugs that are defined as hazardous or toxic chemicals. EPA categorizes several of the antineoplastic agents as toxic wastes, while many states are more stringent and include as carcinogens certain cytotoxic drugs and hormonal preparations. EPA also allows exemptions from toxic waste regulations for small quantity generators, whereas certain states do not. It is critical to research these regulations when disposal procedures are being established. /Antineoplastic agents/
/PRECAUTIONS FOR ANTINEOPLASTIC AGENTS:/ If the biological safety cabinet is equipped with a drainpipe and valve, it may be used to collect rinse water. The collection vessel used must fit well around the drain valve and not allow splashing. Gauze may be used around the connection to prevent aerosol from escaping. The collection vessel must have a tight fitting cover, and all rinse water (gauze, if used) must be disposed of as contaminated waste. /Antineoplastic agents/

Use and Manufacturing

【Use and Manufacturing】
Methods of Manufacturing

Preparation: J. Adams et al., WO 9613266; eidem, US 5780454 (1996, 1998 both to Pro-Script)
【Usage】

It is used as a medicine to treat some refractory disease, for example relapsed multiple myeloma and mantle cell lymphoma.

Biomedical Effects and Toxicity

【Pharmacological Action】
- Substances that inhibit or prevent the proliferation of NEOPLASMS.
【Therapeutic Uses】
Antineoplastic Agents; Protease Inhibitors
Bortezomib injection is indicated for the treatment of patients with multiple myeloma who have received at least 1 prior therapy. /Included in US product label/
Bortezomib injection is indicated for the treatment of patients with mantle cell lymphoma who have received at least 1 prior therapy. /Included in US product label/
【Biomedical Effects and Toxicity】
Following intravenous administration of 1 mg/sq m and 1.3 mg/sq m doses to 24 patients with multiple myeloma (n=12, per each dose level), the mean maximum plasma concentrations of bortezomib (Cmax) after the first dose (Day 1) were 57 and 112 ng/mL, respectively.
In subsequent doses, when administered twice weekly, the mean maximum observed plasma concentrations ranged from 67 to 106 ng/mL for the 1 mg/sq m dose and 89 to 120 ng/mL for the 1.3 mg/sq m dose. The mean elimination half-life of bortezomib upon multiple dosing ranged from 40 to 193 hours after the 1 mg/sq m dose and 76 to 108 hours after the 1.3 mg/sq m dose. The mean total body clearances was 102 and 112 L/hr following the first dose for doses of 1 mg/sq m and 1.3 mg/sq m, respectively, and ranged from 15 to 32 L/hr following subsequent doses for doses of 1 and 1.3 mg/sq m, respectively.
The mean distribution volume of bortezomib ranged from approximately 498 to 1884 L/sq m following single- or repeat-dose administration of 1 mg/sq m or 1.3mg/sq m to patients with multiple myeloma. This suggests bortezomib distributes widely to peripheral tissues. The binding of bortezomib to human plasma proteins averaged 83% over the concentration range of 100 to 1000 ng/mL.
It is not known whether bortezomib is excreted in human milk.
The body distribution of total radioactivity (TR) and bortezomib was investigated in male Sprague-Dawley rats after single and repeated iv (bolus) administration with (14)C-labelled bortezomib (VELCADE) (0.2 mg/kg; 0.28 MBq./kg). Bortezomib was dosed on days 1, 4, 8, and 11 (ie a clinical dosing cycle) and the animals were sacrificed at selected time points following single and repeated dose administration for the quantification of TR in blood, plasma, and various tissues by liquid scintillation counting following organ dissection or by quantitative whole body autoradiography. In selected tissues, bortezomib levels were determined by LC-MS/MS. In general, plasma TR levels were less than 10% of the corresponding blood concentrations. TR was rapidly and widely distributed to the tissues with only limited penetration into the central nervous system (CNS). In the tissues, highest levels of TR were measured in bortezomib-eliminating organs (liver and kidney), lymphoid tissues, and regions of rapidly dividing cells (e.g. the bone marrow, intestinal mucosa). Low TR concentrations were found in the CNS (tissue-to-blood ratio of approximately 0.05 after repeated dosing). With the exception of the liver, TR consisted almost exclusively of the parent drug. Tissue concentrations of TR and bortezomib increased up to about threefold from the first to the third dose administration, after which they remained constant. No undue tissue accumulation of TR and of bortezomib was observed in rats following a full clinical dosing cycle of bortezomib. [Hemeryck A et al; Cancer Chemother Pharmacol 60 (6): 777-87 (2007)] PubMed Abstract
... Bortezomib is rapidly distributed into tissues after administration of a single dose, with an initial plasma distribution half-life of less than 10 minutes, followed by a terminal elimination half-life of more than 40 hours. Maximum proteasome inhibition occurs within 1 hour and recovers close to baseline within 72 to 96 hours after administration. Bortezomib is primarily metabolized by oxidative deboronation to one of two inactive enantiomers that are further processed and eliminated, both renally and in bile. Bortezomib has been shown to be a substrate of several cytochrome P450 isoenzymes using in vitro systems. ... [Schwartz R, Davidson T ; Oncology (Williston Park) 18 (14 Suppl 11): 14-21 (2004)] PubMed Abstract